📄️ BACnet
Pull-type. BACnet device of a building's plant (a controller, an air handling unit, a chiller, a VAV box, a meter, or a BMS front end) whose objects Director reads, subscribes to, and inventories over BACnet/IP.
📄️ Cisco MDT
Listener for the model-driven telemetry Cisco IOS XR, IOS XE and NX-OS routers dial out over gRPC, TCP or UDP, writing every row of a telemetry message as a record.
📄️ DNP3
Pull-type. DNP3 outstation (a substation's RTU, a protection relay or another IED) whose points and events Director reads as a master over TCP, directly or through the terminal server in front of its serial line.
📄️ DNS Check
Pull-type. DNS Check of one name at a resolver from Director, writing the response code, the records and how fast the answer comes, with the state the name is in, as ECS documents.
📄️ eStreamer
Pull-type. Cisco Firepower eStreamer client receiving security events via polling.
📄️ EtherNet/IP
Pull-type. Rockwell Automation Logix controller (a ControlLogix or CompactLogix) or a Micro800 whose tags Director reads by name over EtherNet/IP (CIP).
📄️ gNMI
Pull-type. Network device (Cisco IOS XR, IOS XE and NX-OS, Juniper, Arista, Nokia, or any other that speaks gNMI) whose streaming telemetry Director subscribes to over gRPC.
📄️ gNMI Dial-out
Listener for the gNMI telemetry Nokia SR OS routers publish when they dial out, writing a record for every notification and list entry.
📄️ HTTP
HTTP server accepting POST requests with multiple authentication methods, TLS encryption, and customizable response handling.
📄️ HTTP Check
Pull-type. HTTP Check of one URL from Director, writing its status code, timings, TLS certificate and whether its body holds a text, with the state the service is in, as ECS documents.
📄️ ICMP Check
Pull-type. ICMP Check of one host from Director, writing how many echoes come back and how fast, with the state the host is in, as ECS documents.
📄️ IEC 104
Pull-type. IEC 60870-5-104 controlled station (a substation's RTU, a protection relay, or a plant controller) whose points and events Director reads as a controlling station over TCP or TLS.
📄️ IPAM
Pull-type. IPAM sweep of one IPv4 subnet from Director, writing which addresses are in use, their open ports and names, and how full the subnet is, from datasets, as ECS documents.
📄️ IPFIX
IPFIX flow collector over UDP with multi-worker support and NetFlow v9 template handling.
📄️ Juniper JTI
Pull-type. Junos device whose OpenConfig telemetry Director subscribes to over Juniper's JTI gRPC service, a subscription per group of sensors.
📄️ Modbus
Pull-type. Modbus server (a PLC, a meter, a drive, or a gateway) whose registers Director reads over Modbus/TCP, or RTU or ASCII carried over TCP.
📄️ NetFlow
NetFlow flow collector over UDP with multi-worker support and configurable buffer sizes.
📄️ OPC UA
Pull-type. OPC UA server (a PLC, a protocol gateway, a SCADA or historian, or an edge server) whose nodes Director reads on an interval or subscribes to.
📄️ Siemens S7
Pull-type. Siemens S7 PLC (an S7-300, S7-400, S7-1200, or S7-1500, or a LOGO! by TSAP) whose data blocks, inputs, outputs, markers, timers, and counters Director reads over S7comm.
📄️ sFlow
sFlow sampling collector over UDP with multi-worker support.
📄️ SMTP
SMTP server receiving email messages with authentication, STARTTLS or implicit TLS, and JSON conversion.
📄️ SNMP
Pull-type. SNMP poller reading one switch, router, or firewall for its interfaces, health, and inventory, from datasets, as ECS documents.
📄️ SNMP Trap
SNMPv1/SNMPv2c/SNMPv3 trap receiver with authentication/privacy protocols and MIB integration.
📄️ Syslog
Syslog server accepting UDP or TCP log messages with optional TLS and configurable framing.
📄️ TCP
TCP listener with TLS, configurable framing modes, connection management, and buffering options.
📄️ TCP Check
Pull-type. TCP Check of one host's port from Director, writing whether it takes connections, how fast, and how many are lost, with the state the service is in, as ECS documents.
📄️ TFTP
TFTP server accepting file uploads with IP-based device mapping and automatic file content processing.
📄️ TLS Check
Pull-type. TLS Check of one service's handshake from Director, asking it to start TLS where its protocol begins in the clear, writing its TLS version, cipher, certificate and days left, with the state the service is in, as ECS documents.
📄️ UDP
UDP listener for high-volume message ingestion with configurable workers and buffering.
📄️ Website
Pull-type. Website check of one web page, loaded in Director's headless browser, writing its timings, Web Vitals, requests, console, screenshots and advice, with the state the page is in, as ECS documents.